Przeglądanie stron 224
7-25
disk Commands
If you specified the /view_changeable switch, the command
displays an X in this column for those disks on which you can enable
log errors.
The Interval Timer (secs.) Column
The Interval Timer (secs.) column displays the number of seconds
specified for the exception reporting interval. If you specified the /
view_changeable switch, the command displays an X in this
column for those disks on which you can set the number of seconds
for the exception reporting interval.
The Report Count Column
The Report Count column displays the number of times you
specified for exceptions to be reported. You specify this number by
using the disk set smart command’s /report_count switch.
The Error Count Column
The Error Count column displays the number of errors that
S.M.A.R.T. encountered on the disk.
If you specified the /view_changeable switch, the command
displays an X in this column for those disks on which you can enable
the recording of errors that S.M.A.R.T. encounters on the disk.