Channel#
Channel number of the device to be updated.
ID#
Device number of the device to be updated.
ChunkSize#
Chunk size, in bytes, to be used to update the rmware. For enclosures, the default value is 65536 bytes.
Note: For SATA drives, the chunk size must be a multiple of 512.
Filename
Name of the rmware update le.
Mode#
Firmware update mode.
Valid values for physical devices are:
3-(SATA) Download with offsets and save image for immediate and future use
7-(SAS) Download microcode with offsets, save, and activate
Valid values for enclosures are:
DEFER-Download microcode only; requires system reset or power cycle to activate.
Noprompt
Optional parameter that suppresses alert messages.
26Proprietary and Condential to PMC-Sierra, Inc.