Detailed information on using the Storage Manager application can be found in the online help.
Using the Command line utility
To get information about the controller run:
# /usr/StorMan/arcconf getconfig 1 AD
Controllers found: 1
----------------------------------------------------------------------
Controller information
----------------------------------------------------------------------
Controller Status : OK
Channel description : SCSI
Controller Model : 2130S
Controller Serial Number : 267a69
BIOS Version : 5.1-0 (8832)
Firmware Version : 5.1-0 (8832)
Driver Version : 1.1-5 (2412)
Physical Slot : 1
Copyback enabled : No
Background consistency check enabled: No
Defunct disk drive count : 0
Logical devices/Failed/Degraded : 1/0/0
Command completed successfully.
To get information about the disk array(s), run:
# /usr/StorMan/arcconf getconfig 1 LD