Technical Specifications
Advanced Power and Cooling (APC) Modules
Input Voltage: 100–240 VAC
Current Rating: 6–2.5 Amps
Input Frequency: 50–63 Hz
Outputs:
+5 V @ 37.5 A
+12 V @ 20.0 A
+3.3 V @ 1.0 A
Maximum Average Output Power: 430 Watts
Maximum Peak Output Power: 491 Watts
Cooling: Variable speed fans, 3 per APC unit rated at 20cfm
each. Total of 6 fans per enclosure
Note: APC units are hot-swappable.
Note: Adaptec Storage Enclosures do not support single APC
configurations due to thermal requirements.
Note: In the event of a power supply failure, the fans in the
failed supply will continue to operate on power provided by
the redundant APC unit.
Temperature
Operating: 5 ° C to +40 ° C
Storage: -40 ° C to +70 ° C
Maximum rate of temperature change: 20 ° C per hour
Humidity
Relative Humidity Operating: 10% to 80%, noncondensing
Maximum rate of operational humidity change: 10% per hour
Relative Humidity Storage: 5% to 95%, noncondensing