Appendix B: Understanding RAID 74
RAID 5 Arrays
A RAID 5 array is built from a minimum of three disk drives, and uses data striping and parity
data to provide redundancy. Parity data provides data protection, and striping improves
performance.
Parity data is an error-correcting redundancy that’s used to re-create data if a disk drive fails.
In RAID 5 arrays, parity data (represented by Ps in the next figure) is striped evenly across the
disk drives with the stored data.
Drive segment size is limited to the size of the smallest disk drive in the array. For instance, an
array with two 250 GB disk drives and two 400 GB disk drives can contain 750 GB of stored
data and 250 GB of parity data, as shown in this figure.
Disk Drive 1
Disk Drive 2
Disk Drive 3
Disk Drive 4
250 GB
250 GB
400 GB
400 GB
Drive Segment Size
(Smallest Disk Drive)
Disk Drive 2
Disk Drive 3
Disk Drive 4
Disk Drive 1
1 4 ... P
2 5 ... 748
3 P ... 749
P 6 ... 750
Unused Space = 150 GB
Disk Drives in Logical Drive RAID 5 Logical Drive = 750 GB plus Parity
Unused Space = 150 GB
Przeglądanie stron 73
1 2 ... 69 70 71 72 73 74 75 76 77 78 79 ... 112 113

Komentarze do niniejszej Instrukcji

Brak uwag

Kustom DE50 manuali

Manuali dei proprietari e guide per l'utente per Amplificatore audio per auto Kustom DE50.
We fornisce 1 manuali pdf Kustom DE50 per scaricare gratuitamente in base al tipo di documento: Manuale Utente


Kustom DE50 Manuale Utente (12 pagine)


Marchio: Kustom | Categoria: Car audio amplifiers | Dimensione: 4.31 MB |

 




Più prodotti e manuali per Amplificatore audio per auto Kustom

Modelli Tipo di Documento
Nessuno