3-106
container Commands
Active, not protected,
battery reconditioning
The status of the write cache for this array is as
follows:
Active – The write cache can accept write oper-
ations from the array.
Not protected – The write cache is force-
enabled. Thus, the write cache accepts write
operations even if write data could be lost due
to no battery present or a bad battery on the
controller.
This status also indicates that the battery is
being reconditioned.
Active, protected The status of the write cache for this array is as
follows:
Active – The write cache can accept write oper-
ations from the array.
Protected – The write cache is enabled only if a
battery is present and its status is OK.
This status also indicates that the controllers
battery is present and its status is OK.
Inactive, battery low The status of the write cache for this array is as
follows:
Inactive – The write cache cannot accept write
operations from the array.
Battery low – This controllers battery power is
low.
Inactive, battery not
present
The status of the write cache for this array is as
follows:
Inactive – The write cache cannot accept write
operations from the array.
Battery not present – This controller has no
battery.
Inactive, battery
reconditioning
The status of the write cache for this array is as
follows:
Inactive – The write cache cannot accept write
operations from the array.
Battery low – The controller’s battery is being
reconditioned.
Table 3-7 Values for Write Cache Status (Continued)
Value Meaning