Option: MaximumLogicalUnit
Definition: This command allows the user to specify how
many LUNs the SCSI bus scans for during system
initialization.
Data Type: REG_DWORD
Possible Values: 0-8 (Windows NT 4), 0-32 (Windows 2000/XP/Server 2003)
Default Value: 8 (Windows NT 4), 32 (Windows 2000/XP/Server 2003)
----------------------------------------------------------------
Option: NumberOfRequests
Definition: Specifies the maximum number of outstanding or
concurrent requests that can be delivered to
the SCSI adapter.
Data Type: REG_DWORD
Possible Values: 16-512
Default Value: 255
----------------------------------------------------------------
Option: DisableTaggedQueuing
Definition: If present, tells the SCSI adapter to
disable tagged queuing for all devices.
Data Type: REG_DWORD
Possible Values: N/A
Default Value: N/A
----------------------------------------------------------------
Option: DisableDisconnects
Definition: If present, tells the SCSI adapter not to
allow any target device disconnect privileges
for I/O.
Data Type: REG_DWORD
Possible Values: N/A
Default Value: N/A
----------------------------------------------------------------
Option: DisableMultipleRequests
Definition: Limits the number of commands to each logical
unit to one.
Data Type: REG_DWORD
Possible Values: N/A
Default Value: N/A
----------------------------------------------------------------
=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-
(c) 2008 Adaptec, Inc. All Rights Reserved.
This software contains the valuable trade secrets of Adaptec or its
licensors. The software is protected under international copyright
laws and treaties. This software may only be used in accordance with
the terms of its accompanying license agreement.
No part of this publication may be reproduced, stored in a retrieval
system, or transmitted in any form or by any means, electronic,
mechanical, photocopying, recording or otherwise, without prior
written consent of Adaptec, Inc.,
691 South Milpitas Blvd.,Milpitas, CA 95035
Przeglądanie stron 4
1 2 3 4 5

Komentarze do niniejszej Instrukcji

Brak uwag